Colorado commercial buildings have a natural advantage when it comes to cooling: outdoor air is often cool enough to help maintain comfortable indoor temperatures without relying entirely on mechanical refrigeration.

But many buildings aren’t taking full advantage of that opportunity.

An HVAC economizer allows commercial heating and cooling systems to use favorable outdoor conditions for what’s commonly called free cooling. When properly maintained, this equipment can reduce compressor operation and lower energy consumption.

Unfortunately, economizers are also a frequent source of overlooked HVAC problems. Dampers stick, sensors drift, and controls stop responding correctly, sometimes without anyone noticing.

That’s why economizer inspections should be part of a comprehensive commercial HVAC maintenance program. A functioning economizer can help reduce operating costs, while a malfunctioning one may quietly waste energy for months.

What an HVAC Economizer Does

An HVAC economizer is a system that uses outdoor air to provide cooling when conditions are suitable.

Most commonly found on commercial rooftop units (RTUs) and air handling systems, airside economizers use dampers, sensors, actuators, and controls to regulate how much outdoor air enters the building.

Under normal cooling conditions, an HVAC system uses mechanical refrigeration to remove heat from indoor air. However, when outdoor temperatures are sufficiently low, the economizer can increase outdoor airflow and reduce or temporarily eliminate the need for compressor-based cooling.

How Free Cooling Works

Imagine a commercial office building needs cooling on a mild fall afternoon.

The indoor temperature is rising because of occupants, lighting, computers, and other internal heat sources. Outside, however, the air is considerably cooler.

Instead of immediately running the air conditioning compressors, a properly functioning economizer can introduce more outdoor air to help satisfy the cooling demand.

The system uses dampers to regulate outdoor and return air while maintaining appropriate ventilation and supply-air conditions.

Depending on the equipment, economizer controls may evaluate outdoor temperature, enthalpy, or other conditions before enabling free cooling. It’s important to understand that free cooling doesn’t mean zero energy consumption. Supply fans, controls, and other components still require electricity. The savings come primarily from reducing mechanical cooling demand.

Why Colorado’s Climate Is Ideal for Free Cooling

Colorado’s climate offers favorable conditions for commercial HVAC economizers.

Many areas experience relatively low humidity, cool nights, and substantial temperature differences between daytime and nighttime conditions.

These characteristics can create opportunities to use outdoor air for cooling during portions of spring, fall, and even some winter days.

Cooling Isn’t Just a Summer Requirement

Commercial buildings often need cooling even when outdoor temperatures feel comfortable.

Office equipment, lighting, occupants, manufacturing processes, and other internal heat sources generate warmth throughout the year.

A large commercial property may require cooling in certain spaces while outdoor temperatures are relatively low.

When outdoor air conditions are appropriate, an economizer can help meet that demand without operating compressors as frequently.

Lowering Commercial Building Energy Costs

Cooling can represent a significant portion of a commercial property’s energy expenses.

Reducing compressor runtime may lower electricity consumption, especially in buildings with substantial internal cooling loads.

Economizers can also complement other efficiency measures, including building automation improvements, properly maintained filters, and optimized operating schedules.

For additional strategies, explore our guide to reducing commercial HVAC building energy costs.

Actual savings depend on equipment configuration, building loads, local weather, control settings, and maintenance condition.

Economizers at Altitude: Colorado Springs and Southern Colorado

Higher-elevation communities present additional considerations for commercial HVAC design and operation.

Colorado Springs sits at approximately 6,000 feet above sea level, while many surrounding Southern Colorado communities experience similarly elevated conditions.

At higher altitudes, air density decreases. This can affect fan performance, airflow calculations, heat transfer, and equipment capacity.

Why Altitude Matters

An economizer’s effectiveness depends partly on delivering enough suitable outdoor air to meet the building’s cooling requirements.

At higher elevations, the same volume of air contains less mass than it would at sea level.

That means equipment selection, airflow measurements, and control strategies should account for local conditions.

An economizer designed or adjusted without considering altitude may not perform as intended.

However, elevation doesn’t eliminate the benefits of free cooling.

Colorado Springs’ relatively dry climate and seasonal temperature patterns can provide favorable economizer operating conditions when equipment is properly designed and maintained.

Commercial HVAC Economizer Service in Colorado Springs

Commercial buildings in Colorado Springs, Pueblo, and surrounding Southern Colorado communities may benefit from economizer inspections, control adjustments, and airflow evaluations.

Thrivaire provides commercial HVAC services in Colorado Springs to help building owners evaluate rooftop units, economizers, and other mechanical equipment.

Whether you’re managing an office property, industrial facility, or institutional building, proper economizer operation can be an important part of maintaining efficient HVAC performance.

Signs Your Economizer Isn’t Working

One of the biggest challenges with economizer failures is that they aren’t always obvious.

A rooftop unit may continue heating and cooling the building even when its economizer isn’t operating correctly.

The building remains comfortable, but the system may consume more energy than necessary.

Common warning signs include:

Higher-Than-Expected Cooling Costs

If compressors continue running during mild outdoor conditions, the economizer may not be taking advantage of available free cooling.

Unexplained increases in electricity consumption can justify a closer look at HVAC controls and operating sequences.

Dampers Stuck Open or Closed

Economizer dampers regulate outdoor and return airflow.

When dampers become stuck closed, the system may miss opportunities for free cooling and, depending on the configuration, fail to deliver intended outdoor ventilation.

Dampers stuck open can introduce excessive outdoor air during unsuitable conditions, increasing heating or cooling demand and potentially affecting indoor comfort.

Faulty Sensors

Economizers depend on sensors to determine when outdoor conditions are suitable.

A sensor providing inaccurate readings may prevent economizer operation or cause the system to introduce outdoor air at inappropriate times.

Failed Actuators or Control Components

Damper actuators, linkages, wiring, and control boards can deteriorate over time.

A failed actuator may prevent dampers from moving even when the building automation system calls for economizer operation.

Poor Temperature Control

Unexpected temperature swings, excessive heating or cooling demand, and inconsistent supply-air temperatures may indicate economizer or control problems.

These symptoms can have several causes, so professional troubleshooting is important.

Why Economizer Problems Go Unnoticed

Economizer failures can persist because the mechanical cooling system continues compensating for the problem.

Without routine functional testing, a failed economizer may remain undetected until an energy review, inspection, or major equipment problem reveals it.

This is one reason preventive maintenance should evaluate economizer operation rather than simply confirm that the HVAC unit turns on.

Repair, Upgrade, or Replace?

A malfunctioning economizer doesn’t automatically mean the entire rooftop unit needs replacement.

In many cases, targeted repairs can restore proper operation.

When Repair Makes Sense

Common repairs may involve replacing sensors, repairing damper linkages, correcting control settings, or replacing failed actuators.

If the rooftop unit is otherwise reliable and in good condition, repairing the economizer may be the most economical approach.

When an Upgrade Is Worth Considering

Older economizer controls may lack the capabilities of newer systems.

Depending on equipment compatibility, updated sensors, controllers, or control sequences may improve performance and provide better monitoring.

Some buildings may also benefit from integrating economizer operation with building automation systems.

When Replacement Is the Better Option

If the rooftop unit has extensive mechanical deterioration, recurring failures, or significant efficiency problems, replacement may deserve consideration. Economizer repairs should be evaluated alongside the condition and remaining useful life of the entire system.

Our guide to when to replace a commercial rooftop unit explains the factors building owners should consider before investing in major repairs.

At Thrivaire, we evaluate whether repair, retrofit, or replacement provides the best long-term value rather than automatically recommending new equipment.

FAQs

What is an HVAC economizer?

An HVAC economizer is a system that uses suitable outdoor air to provide cooling, reducing the need for mechanical refrigeration. It typically uses dampers, sensors, actuators, and controls to manage outdoor airflow.

How much energy can an economizer save?

Savings depend on climate, building cooling loads, equipment efficiency, control settings, and maintenance. Buildings with significant cooling demand during mild weather may benefit substantially, but results should be evaluated individually.

Do commercial HVAC economizers work in winter?

Yes. Some commercial buildings require cooling during winter because of internal heat loads. When outdoor conditions are suitable and system safeguards permit, an economizer may provide cooling without relying entirely on compressors.

Why do HVAC economizers fail?

Common causes include stuck dampers, failed actuators, inaccurate sensors, damaged linkages, control problems, and inadequate maintenance.

Can an economizer cause higher energy bills?

Yes. A malfunctioning economizer may increase energy consumption by preventing free cooling or introducing excessive outdoor air during unfavorable conditions.

How often should commercial HVAC economizers be inspected?

Economizer inspections should be included in scheduled HVAC maintenance. The appropriate frequency depends on equipment type, operating conditions, manufacturer recommendations, and facility requirements.

Do all commercial rooftop units have economizers?

No. Economizer requirements and configurations depend on equipment type, capacity, climate zone, applicable energy codes, and the building’s design. Some units have factory-installed economizers, while others use optional or retrofit systems.

Keep Your Commercial HVAC Economizer Working with Thrivaire

Colorado’s climate creates valuable opportunities to reduce commercial cooling expenses through properly functioning economizers. But those savings depend on equipment that operates as intended.